FCoV検査キット

FCoV検査キット

カテゴリー: ,

説明

FCoV検査キット

JNCMED Felivet FCoV Ag Test is a test cassette to detect the presence of Feline Coron virus antigen (FCoV Ag) in cat’s pleural fluid, ascitic fluid or feces specimen, to provide a reference for diagnosis of Feline Infectious Peritonitis (FIP) infection..

*タイプ: 検出カード

* のために使用される: FCoV Test

*標本: 糞便

*アッセイ時間: 5-10 分

*サンプル: 供給

*保管所: 2-30℃

*有効期限: 製造日から2年間

*カスタマイズされた: 受け入れる

 

Feline Calicivirus Fcv Antigen Rapid Diagnostic Test

Introduction by JNCMED

The Felivet FCoV Ag Test is a test cassette to detect the presence of Feline Coron virus antigen (FCoV Ag) in cat’s pleural fluid, ascitic fluid or feces specimen, to provide a reference for diagnosis of Feline Infectious Peritonitis (FIP) 感染.

材料 Provided by sabrina@jcmedtj.com

1.JNCMED 試験装置は個別に乾燥剤が入ったホイルパウチに入れられています
2.チューブ内のアッセイ溶液
3.使い捨てスポイト
4.滅菌綿棒
5.使用説明書

Principle

The FCoV Ag Rapid Test is based on sandwich lateral flow immunochromatographic assay. The test device has a testing window for the observation of assay running and result reading. The testing window has an invisible T (test) zone and a C (control) zone before running the assay. When the treated sample was applied into the sample hole on the device, the liquid will laterally flow through the surface of the test strip and react with the pre-coated monoclonal antibodies. If there is FIPV antigen in the specimen, a visible T line will appear. The C line should always appear after a sample is applied, which indicates a valid result. By this means, the device can accurately indicate the presence of FIPV antigen in the specimen.

特徴

1. 簡単操作

2. 高速読み取り結果

3. 高い感度と精度

4. リーズナブルな価格と高品質

試験手順

Allow all materials (including specimens and test equipment) to recover to °C.15-25 before testing is performed
– Remove the test equipment from the foil bag and place it horizontally.
– Collection of pleural or peritoneal fluids from patient cats for filtration and centrifuge to remove impurities. Use transparent liquid in detection. In the case of pleural fluid or ascites fluid, use a dropper to prepare 1 drop (approx. μL 40) into the sample hole “S” of the test equipment. and then immediately put 2 drops (about 80μL) of detection buffer into the sample hole. Note: if the liquid specimen is sufficient, put about 0.5 mL of liquid specimen into the detection buffer and mix well for direct use.
– In the case of stool specimens, the tip of the cat’s dung is collected with a swab. Insert the swab into the supply detection buffer tube to dilute. shake to make it fully resolved and use the mixture in the detection.
– Explain the results within 15-20 分. The results after 20 minutes are considered invalid

 

結果の解釈

※ポジティブ (+): The presence of both “C” line and zone “T” line, Tラインがはっきりしていても曖昧でも.

※ネガティブ (-): 鮮明なCラインのみが表示されます. Tラインなし.

無効: Cゾーンにカラーラインが出ない. Tラインが出ても構わない.

 






    迅速検査キット:
    迅速検査キット