Kit de prueba rápida para múltiples drogas JNCMED™ (Orina) Cortar
What are drug test cut-off levels?
La prueba de drogas detecta la presencia de drogas y metabolitos de drogas utilizando niveles de corte para determinar si una muestra da positivo o negativo para el uso de una droga específica..
Kit de prueba rápida para múltiples drogas JNCMED™
JNCMED™ Multi-drug Rapid Test Kit (Orina) es un inmunoensayo visual rápido para la detección cualitativa de drogas de abuso en muestras de orina humana. El kit de prueba detecta OPI, FREGAR, BZO, REUNIÓ, MDMA, PCP, THC, BAR, OXY, TCA, TML, PPX, AMPERIO, MTD, AOC, KET, K2, BUP, CUNA, FYL en orina cualitativamente.
Cut-off Concentrations
Accept OEM
Drug Name | Abbreviation | Cortar | |
Especificación | Customization | ||
Anfetamina | AMPERIO | 1000 de/mL | 500/300 de/mL |
Secobarbita | BAR | 300 de/mL | 200 de/mL |
Buprenorphine | BUP | 10 de/mL | / |
Benzodiazepines | BZ0 | 300 de/mL | 200 de/mL |
Cocaína | AOC | 300 de/mL | 150 de/mL |
Cotnine | CUNA | 200 de/mL | / |
EDDP | EDDP | 300 de/mL | 100 de/mL |
Alcohol | ETG | 1000 de/mL | 500 de/mL |
Fentanyl | FYL | 200 de/mL | 100/10 de/mL |
Synthetic Marijuana | K2 | 50 de/mL | / |
Xetamine | KET | 100 de/mL | 500 de/mL |
(±)3,4-Methylenedioxyme thamphetamine | MDMA | 500 de/mL | 1000 de/mL |
Metanfetamina | MET/MAMP | 1000 de/mL | 500/300 de/mL |
Morphine | MOP/MOR | 300 de/mL | 100 de/mL |
Methadone | MTD | 300 de/mL | 200 de/mL |
opiáceos | OPI | 2000 de/mL | / |
Oxycodone | OXY | 100 de/mL | 300 de/mL |
Phencyclidine | PCP | 25 de/mL | 10 de/mL |
Pregabalin | PGB | 5000 de/mL | / |
Propoxyphene | PPX | 300 de/mL | 100 de/mL |
Carisoprodol | SOMA | 2000 de/mL | / |
Tricyclic antidepressant | TCA | 1000 de/mL | 500 de/mL |
Tetrahydrocannabinol | THC | 50 de/mL | 25/20 de/mL |
Tramadol | TRA/TML | 300 de/mL | 200/100 de/mL |
JNCMED™ Multi-drug Rapid Test Kit Test Principle
Multi-Drug Strips: This kit uses specific antigen-antibody reaction, combining Gold Immunochromatography Assay experiment, highly specific and sensitive competition method to detect OPI, FREGAR, BZO, REUNIÓ, MDMA, PCP, THC, BAR, OXY, TCA, TML, PPX, AMPERIO, MTD, AOC, KET, K2, BUP, CUNA, FYL in urine.
When testing, urine moving forward under the action of chromatography. If the concentration of the analyte in urine is below the cut-off level, colloidal gold antibodies can not be combined with the analyte in the urine completely, and the rest of colloidal gold antibodies will be captured by the conjugated antigen on the NC membrane, appearing a visible red precipitate line (test line T). If the concentration of the analyte in urine is higher than the cut-off level, the analyte in urine can combine all of colloidal gold antibodies, thus no colloidal gold antibodies can combine with the antigen conjugated on the NC membrane, so no red line appeared in the test area(T). Whether the analyte exists in the urine or not, a red line (control line C) will always appear in the control area (C) to serve as a procedure control.